Conference

 Thank you to all the members and business that support BCOSSA’s ongoing work in the industry.

Unfortunately due to insufficient presales of delegate tickets or exhibitor space we are cancelling the Conference and Trade Show.

Thank you again for your support.

Be part of the Discussion!

The theme:

Maintaining and Managing Onsite Systems for Success
Come join us for the conversation and educational sessions
Hear from suppliers how to use and maintain their systems
Learn about water flow through soil and its effect on environment
Get Education credits and/or complete your BCOSSA maintenance training
 Suppliers; Don't miss the opportunity to meet professionals and Practitioners directly by signing up for our tradeshow

 

 


News And Events

National Onsite Wastewater Design and Installation Standard Published

Canada Standards Association (CSA) has now published the first national onsite design and installation code in Canada. The code is the culmination of seven years of effort by over 20 onsite experts from every province and territory in the country. The standard was developed for use by onsite wastewater technicians and professionals and to offer a baseline standard for provincial and federal agencies to develop consistent regulatory frameworks and supporting the Agreement of Internal Trade.

The CSA B-25 12 standard may now be used by ROWP’s and Professionals in BC as “Standard Practice” in accordance with the Sewerage System Regulation. The CSA-B65 standard provides design criteria for daily design flow rates, hydraulic loading rates and linear loading rates that support proper design and installation of onsite wastewater system that will protect public health and the environment. The standard provides methodology that will be easily recognizable to AP’s in BC and can be used as an alternative to the Sewerage System Standard Practice Manual when filing documentation with the health authority.

BCOSSA would like to recognize the support and effort of Tim Wilson ROWP Langley, Frank Hay ROWP Langley and John Rowse B.A.A.C.P.H.I(C) , MA for their participation in developing the CSA-B65 Standard.

Health Authorities to Review and Approve Filings

The Ministry of Healthy Living and Sport has recently released changes to the Sewerage System Regulation that will affect the industry significantly and the way an authorized person will interact with the health authorities. Additionally, the regulation changes include a prescribed standard for “well” setbacks, defines a new category of professional and allows for home owners to install their own systems.

The changes state:

Health Authorities that accept filings and maintenance plans must ensure the proposal will not create a health hazard
Home owners may install their own systems
Septic tanks, Type 2 and 3 systems must be 30 meters from a well supplying domestic water
Practitioner education becomes the responsibility of ASTTBC
The following is a description of the changes and potential effects:

Section 1 The definition of “construct” now allows for all authorized persons to provide supervision to anyone for the purposes of planning, conduct site assessments, install, repair or alter a sewerage system or in the case of maintenance, supervise the maintenance of the system.

This change provides an Authorized Person the power to supervise anyone to do any work outlined within the Sewerage System Regulation. However, the Authorized Person must submit the filing documentation, Letter of Certification and supervise the quality of the work performed

A new section has been added to the regulation, section 2.1 “Prescribed health hazards and regulated activities” that replaces the definition of health hazard but more importantly outlines the responsibilities of health officers (environmental health officers) with regard to proactive assessment.

The section states that a prescribed “health hazard” occurs where the proposed construction or maintenance of a system will, in the opinion of the health offices, cause a health hazard. The wording in the section outlines the necessity of the health officer to review the proposal, which in the case of the Sewerage System Regulation is the file documents and maintenance plan, to ensure the system will not create a health hazard when it is constructed and throughout the maintenance of the system.

The new section 2.1 in combination with section 11 which defines the health officer’s power to make orders and carry out inspections in accordance with the Public Health act, provide the basis for a similar process as was in place prior to the advent of the Sewerage System Regulation. Based on this it would be advisable for all Authorized Persons to contact their health authority office to ensure that proper procedures are followed.

A new section 3.1 has been added to the regulation, section 3.1 “Setback from wells” is a prescriptive section that replaces the setbacks to wells outlined in the Sewerage System Standard Practice Manual (SPM) . Section 3.1 requires Sewerage Systems be located greater than 30 meters (100 ft) from a well that supplies domestic water. This section does not separate the distribution area from the treatment unit (septic tank, type 2 ) which makes the prescribed standard more restrictive than any other similar standard in Canada or North America. It is also worth noting that the setbacks to other sources of domestic water remain within the SPM.

Section 3.1 does provide a mechanism to site systems closer to domestic wells, to move a system to less than 30 meters from a well if a “Professional competent in the area of hydrogeology” provides advice that the system would likely not cause a health hazard as a result of the reduced setback. The section is unclear as to whose responsibility it is to obtain the advice but it must be submitted to the health authority. Authorized persons seeking to obtain the services of hydrogeology professional may wish to contact the BC Ground Water Association at

http://www.bcgwa.org/.

Section 6 has been amended to allow for home owners to construct or maintain a sewerage system on their own land as long as the owner is supervised by an Authorized Person. This is consistent with and clarifies section 1 which allows supervision of anyone to do work under the regulation. The Authorized Person remains responsible for the submission of filing documents, maintenance plans and letters of certification.

Section 7 of the regulation has been amended to ensure all training occurring through an institution based in BC is recognized by the Applied Science Technicians and Technologists of BC replacing BCOSSA in this role.

These regulatory amendments came into effect June 25th, 2010, Authorized Persons should contact their local health authority regarding the status of ongoing file documentation and to ensure they receive a written assurance that their file proposal is acceptable before proceeding to construct or maintain.

Q & A from the Ministry of Healthy Living and Sport

We have asked the Ministry of Healthy Living and Sport for clarification of these setbacks and the questions and replies from
Rupert Benzon are as follows:

Question 1: What is the setback to watertight treatment tanks (15m or 30m)?

Answer: 15m setback distance to holding tanks, and 30m setback to septic tanks.

Question 2. What is the setback to collection and delivery piping?

Answer: If you are referring to the solid pipe which runs from the septic tank to the distribution box, as well as the pipe from the

structure (house) to the septic tank, there is no minimum setback required.

Question 3. For an existing filing what is to be done where?

a. The filing has setback reductions but these have been made by a professional who is not a hydrogeologist.
Answer: Please note that in the SSR, the definition of 'construct' includes the planning of a sewerage system. Therefore, construction of the system can be considered to have commenced at the planning stage (i.e. when the filing for the system has been submitted) and the recent amendments to the SSR would not apply in these cases.

b. The filing has tanks within 30 m of a well.
Answer: The same holds true for septic tanks within 30 m.

Question 4. What is to be done in repair situations where a system was constructed under the SSR and does not meet this new standard (for example, where there was a setback reduction by a non hydrogeologist)? Note that the repair might be to a part of the system not within the setback.
Answer: Repairs which are being implemented on systems which have already been constructed under the SSR , do not have to meet the new setback standard (i.e. if the existing system was built with setback reductions).

Accredited Treatment Units

Accredited Sewage Treatment Methods Available In British Columbia as Listed by the Appropriate Agencies as at February 2, 2013

Listed Alphabetically by Name of Primary Manufacturer

The BC Onsite Sewage Association is not endorsing or approving any of the products listed below. This list is provided as part of an awareness program.

BCOSSA has attempted to list those products that are installed in BC. If your product is not listed and it has accreditation, please contact the BCOSSA office and the listing will be changed accordingly.

Standards Council of Canada is a federal government agency that has the authority to accredit standard setting bodies and bodies to test to those standards. The SCC also accredits bodies to conduct certification programs that monitor the manufacturing process and the technologies' performance to ensure compliance to the original standard and tests.

The SCC has accredited the NSF International and the Bureau d'normaization du Quebec (BNQ) to develop standards and testing protocols.

The SCC audits the programs and work conducted by NSF and BNQ to ensure compliance to the National Standards of Canada.

Products and technologies not listed below that are installed in BC are not covered under the Standards Council of Canada protocols or any standard as recognized under the National Standards of Canada system.

In the USA, the counterpart to SCC is ANSI - American National Standards Institute. ANSI is a recognized body under the SCC rules.

The CAN/BNQ 3680-600/2009 standard, as approved by the SCC, is a recent standard and no technologies have been tested to date to that standard. However, the BNQ has a standard, NQ 3680, with Class I, Class II, Class II, Class IV and Class V that may or may not match to the BC Type 1, 2 or 3.

BNQ standard NQ3680 Class II directly relates the BC Sewerage System Regulation Treatment Method Type 2. BNQ standard NQ3680 Class III, Class IV and Class V have a BOD5 and TSS of 15 mg/l each and do not directly relate to BC's Type 3.

Similarly, the NSF International Standard may demonstrate compliance to BC Type 2 or 3.

It is recommended to authorized persons under the BC Sewerage System Regulation that they should have copies of the NSF International or the BNQ test reports to satisfy themselves that the test results confirm compliance to the BC Sewerage System Regulations for the Treatment Method Type 2 and Type 3 as well as the BC Standard Practice Manual for the Type 2 10/10 treatment method.

The Province of Quebec allows direct discharge of the effluent whereas the Province of BC under the Sewerage System Regulation does not. Therefore, the following listing does not include models with open bottom tank.

The following list identifies the NSF International and BNQ standards that meet directly the BC Treatment Method as stated in the BC regulation.

Primary Manufacturer

Product Brand Name

BC Distributor

Model Number

Certifying Agency

Type

BioMicrobics Inc.

MicroFAST®

JRSC Ltd.

MicroFAST® 0.375

NSF Standard 40

Type 2

http://jrscltd.com/

MicroFAST® 0.5

NSF Standard 40

Type 2

MicroFAST® 0.625

NSF Standard 40

Type 2

MicroFAST® 0.75

NSF Standard 40

Type 2

MicroFAST® 0.9

NSF Standard 40

Type 2

MicroFAST® 1.5

NSF Standard 40

Type 2

Letter of Approval

MicroFAST® 3.0

NSF Standard 40

Type 2

BioMicrobics Inc.

BioBarrier®

JRSC Ltd.l

BioBarrier® MBR 0.5

NSF Standard 40

Type 3

http://jrscltd.com/

BioBarrier® MBR 0.5-N

NSF Standard 40

Type 3

BioBarrier® MBR 1.0

NSF Standard 40

Type 3

BioBarrier® MBR 1.0-N

NSF Standard 40

Type 3

BioBarrier® MBR 1.5

NSF Standard 40

Type 3

BioBarrier® MBR 1.5-N

NSF Standard 40

Type 3

BioMicrobics Inc.

MicroFAST®

JRSC Ltd.

MicroFAST® 0.5

NSF Standard 245

Type 2

http://jrscltd.com/

MicroFAST® 0.625

NSF Standard 245

Type 2

MicroFAST® 0.75

NSF Standard 245

Type 2

MicroFAST® 0.9

NSF Standard 245

Type 2

MicroFAST® 1.5

NSF Standard 245

Type 2

BioMicrobics Inc.

BioBarrier® - Nitrogen

JRSC Ltd.

BioBarrier® MBR 0.5-N

NSF Standard 245

Type 3

http://jrscltd.com/

BioBarrier® MBR 1.0-N

NSF Standard 245

Type 3

BioBarrier® MBR 1.5-N

NSF Standard 245

Type 3

BioMicrobics Inc.

BioBarrier®

JRSC Ltd.

BioBarrier® 0.5

NSF Standard 350

Type 3

http://jrscltd.com/

BioBarrier® 1.0

NSF Standard 350

Type 3

BioBarrier® 1.5

NSF Standard 350

Type 3

Bionest Technologies Inc.

Bionest

Bionest Technologies Inc.

BNC-1000

NSF Standard 40

Type 2

Website

BNC-1250

NSF Standard 40

Type 2

BNC-1500

NSF Standard 40

Type 2

BNC-400

NSF Standard 40

Type 2

BNC-500

NSF Standard 40

Type 2

BNC-600

NSF Standard 40

Type 2

BNC-750

NSF Standard 40

Type 2

OT-100

NSF Standard 40

Type 2

OT-125

NSF Standard 40

Type 2

OT-150

NSF Standard 40

Type 2

OT-40

NSF Standard 40

Type 2

OT-45

NSF Standard 40

Type 2

OT-50

NSF Standard 40

Type 2

OT-55

NSF Standard 40

Type 2

OT-60

NSF Standard 40

Type 2

OT-70

NSF Standard 40

Type 2

OT-75

NSF Standard 40

Type 2

Bionest Technologies Inc.

Bionest

Bionest Technologies Inc.

OT-100

NSF Standard 245

Type 2

Website

OT-125

NSF Standard 245

Type 2

OT-150

NSF Standard 245

Type 2

OT-40

NSF Standard 245

Type 2

OT-45

NSF Standard 245

Type 2

OT-50

NSF Standard 245

Type 2

OT-55

NSF Standard 245

Type 2

OT-60

NSF Standard 245

Type 2

OT-70

NSF Standard 245

Type 2

OT-75

NSF Standard 245

Type 2

Website

SA-3

NQ 3680 Class III

Type 2

SA-4

NQ 3680 Class III

Type 2

SA-5

NQ 3680 Class III

Type 2

SA-6

NQ 3680 Class III

Type 2

SA-3D

NQ 3680 Class V

Type 2

SA-4D

NQ 3680 Class V

Type 2

SA-5D

NQ 3680 Class V

Type 2

SA-6D

NQ 3680 Class V

Type 2

Clearstream Wastewater Systems

Clearwater

NPS Wastewater

500N

NSF Standard 40

Type 2

Website

500NC

NSF Standard 40

Type 2

500NC2

NSF Standard 40

Type 2

500NC3

NSF Standard 40

Type 2

500NCS

NSF Standard 40

Type 2

500NS

NSF Standard 40

Type 2

500NU

NSF Standard 40

Type 2

600N

NSF Standard 40

Type 2

600NC

NSF Standard 40

Type 2

600NC2

NSF Standard 40

Type 2

600NC3

NSF Standard 40

Type 2

600NU

NSF Standard 40

Type 2

750N

NSF Standard 40

Type 2

750NC

NSF Standard 40

Type 2

750NC2

NSF Standard 40

Type 2

800N

NSF Standard 40

Type 2

800NC

NSF Standard 40

Type 2

800NC2

NSF Standard 40

Type 2

1000N

NSF Standard 40

Type 2

1000N-B

NSF Standard 40

Type 2

1000NC

NSF Standard 40

Type 2

1000NC-B

NSF Standard 40

Type 2

1000NCD

NSF Standard 40

Type 2

1000ND

NSF Standard 40

Type 2

1000NSD

NSF Standard 40

Type 2

1200NCD

NSF Standard 40

Type 2

1200ND

NSF Standard 40

Type 2

1500N

NSF Standard 40

Type 2

1500N-B

NSF Standard 40

Type 2

1500NC

NSF Standard 40

Type 2

1500NC-B

NSF Standard 40

Type 2

1500NCD

NSF Standard 40

Type 2

1500ND

NSF Standard 40

Type 2

Consolidated Treatment Systems

Nayadic

CK Ventures

Nayadic M-6A

NSF Standard 40

Type 2

Website

Nayadic M-8A

NSF Standard 40

Type 2

Nayadic M-1050A

NSF Standard 40

Type 2

Nayadic M-1200A

NSF Standard 40

Type 2

Nayadic M-2000A

NSF Standard 40

Type 2

Delta Environmental Products

Whitewater

Canwest Tanks & Ecologic

DF40

NSF Standard 40

Type 2

Website

DF50

NSF Standard 40

Type 2

DF60

NSF Standard 40

Type 2

DF75

NSF Standard 40

Type 2

DF100

NSF Standard 40

Type 2

DF150

NSF Standard 40

Type 2

Delta Environmental Products

Eco-Pod

Canwest Tanks & Ecologic

E50

NSF Standard 40

Type 2

Website

E50FF01

NSF Standard 40

Type 2

E50FF02

NSF Standard 40

Type 2

E50-N

NSF Standard 40

Type 2

E50-N - IM1060

NSF Standard 40

Type 2

E60-FF

NSF Standard 40

Type 2

E60-N

NSF Standard 40

Type 2

E60-N - IM1060

NSF Standard 40

Type 2

E75-FF

NSF Standard 40

Type 2

E75-N

NSF Standard 40

Type 2

E75-N - IM1060

NSF Standard 40

Type 2

E100-FF

NSF Standard 40

Type 2

E100-N

NSF Standard 40

Type 2

E150

NSF Standard 40

Type 2

E150-N

NSF Standard 40

Type 2

Delta Environmental Products

Eco-Pod

Canwest Tanks & Ecologic

E50-N

NSF Standard 245

Type 2

Website

E50-N - IM1060

NSF Standard 245

Type 2

E60-N

NSF Standard 245

Type 2

E60-N - IM1060

NSF Standard 245

Type 2

E75-N

NSF Standard 245

Type 2

E75-N - IM1060

NSF Standard 245

Type 2

E100-N

NSF Standard 245

Type 2

E150-N

NSF Standard 245

Type 2

Fuji Clean USA

CEN5

NSF Standard 450

Type 3

http://www.fujicleanusa.com/     CEN7

NSF Standard 630

Type 3

      CEN10

NSF Standard 900

Type 3

      CE5

NSF Standard 40

Type 2

      CE7

NSF Standard 40

Type 2
      CE10

NSF Standard 40

Type 2

           

Jet, Inc.

Jetbat

Leko Precast

J-500

NSF Standard 245

Type 2

Website

J-500PLT

NSF Standard 245

Type 2

J-600

NSF Standard 245

Type 2

J-750

NSF Standard 245

Type 2

J-750PLT

NSF Standard 245

Type 2

J-800

NSF Standard 245

Type 2

J-800PLT

NSF Standard 245

Type 2

J-1000

NSF Standard 245

Type 2

J-1250

NSF Standard 245

Type 2

J-1500

NSF Standard 245

Type 2

Norweco, Inc.

Norweco Singular

???????????

950-600GPD

NSF Standard 40

Type 2

Website

950-750GPD

NSF Standard 40

Type 2

950-1000GPD

NSF Standard 40

Type 2

950-1250GPD

NSF Standard 40

Type 2

950-1500GPD

NSF Standard 40

Type 2

960-500GPD

NSF Standard 40

Type 2

960-500GPD

NSF Standard 40

Type 2

960-750GPD

NSF Standard 40

Type 2

960-750GPD

NSF Standard 40

Type 2

960-1000GPD

NSF Standard 40

Type 2

960-1250GPD

NSF Standard 40

Type 2

960-1500GPD

NSF Standard 40

Type 2

960LP-500

NSF Standard 40

Type 2

960LP-500

NSF Standard 40

Type 2

960LP-1000

NSF Standard 40

Type 2

960OP-500GPD

NSF Standard 40

Type 2

960OP-500GPD

NSF Standard 40

Type 2

960OP-1000GPD

NSF Standard 40

Type 2

Green 960-500

NSF Standard 40

Type 2

Green 960-500

NSF Standard 40

Type 2

Green TNT-500

NSF Standard 40

Type 2

Green TNT-500

NSF Standard 40

Type 2

Hydro-Kinetic 600

NSF Standard 40

Type 2

Hydro-Kinetic 600

NSF Standard 40

Type 2

TNT-500

NSF Standard 40

Type 2

TNT-500

NSF Standard 40

Type 2

TNT-750

NSF Standard 40

Type 2

TNT-750

NSF Standard 40

Type 2

TNT-1000

NSF Standard 40

Type 2

TNT-1250

NSF Standard 40

Type 2

TNT-1500

NSF Standard 40

Type 2

TNTLP-500

NSF Standard 40

Type 2

TNTLP-500

NSF Standard 40

Type 2

TNTLP-1000

NSF Standard 40

Type 2

TNTOP-500

NSF Standard 40

Type 2

TNTOP-500

NSF Standard 40

Type 2

TNTOP-1000

NSF Standard 40

Type 2

TNTOR-500

NSF Standard 40

Type 2

TNTOR-600

NSF Standard 40

Type 2

Norweco, Inc.

Norweco Singular

???????????

Green TNT-500

NSF Standard 245

Type 2

Website

Green TNT-500

NSF Standard 245

Type 2

Hydro-Kinetic 600

NSF Standard 245

Type 2

Hydro-Kinetic 600

NSF Standard 245

Type 2

TNT-500

NSF Standard 245

Type 2

TNT-500

NSF Standard 245

Type 2

TNT-750

NSF Standard 245

Type 2

TNT-750

NSF Standard 245

Type 2

TNT-1000

NSF Standard 245

Type 2

TNT-1250

NSF Standard 245

Type 2

TNT-1500

NSF Standard 245

Type 2

TNTLP-500

NSF Standard 245

Type 2

TNTLP-500

NSF Standard 245

Type 2

TNTLP-1000

NSF Standard 245

Type 2

TNTOP-500

NSF Standard 245

Type 2

TNTOP-500

NSF Standard 245

Type 2

TNTOP-1000

NSF Standard 245

Type 2

TNTOR-500

NSF Standard 245

Type 2

TNTOR-600

NSF Standard 245

Type 2

Orenco Systems, Inc

AdvanTex

OSI / Eagle Engineering

AdvanTex AX20N

NSF Standard 40

Type 2

Website

AdvanTex AX20RTN

NSF Standard 40

Type 2

AdvanTex AX25RTN

NSF Standard 40

Type 2

AdvanTex AX15-2N

NSF Standard 40

Type 2

AdvanTex AX20-2N

NSF Standard 40

Type 2

AdvanTex AX15-3N

NSF Standard 40

Type 2

AdvanTex AX20-3N

NSF Standard 40

Type 2

Premier Tech Technologies Limited

Eco-Flo

Premier Tech

EFX-400-1

NSF Standard 40

Type 2

Website

EFX-400B-1

NSF Standard 40

Type 2

STB-500-1

NSF Standard 40

Type 2

STB-500-2

NSF Standard 40

Type 2

STB-650-1

NSF Standard 40

Type 2

STB-650-2

NSF Standard 40

Type 2

STB-650-3

NSF Standard 40

Type 2

STB-570P-1

NSF Standard 40

Type 2

STB-570PR-1

NSF Standard 40

Type 2

STB-650B-H1-A-1

NSF Standard 40

Type 2

STB-650B-H1-A-2

NSF Standard 40

Type 2

STB-650B-H1-A-3

NSF Standard 40

Type 2

STB-650B-H1-NA-1

NSF Standard 40

Type 2

STB-650B-H1-NA-2

NSF Standard 40

Type 2

STB-650B-H1-NA-3

NSF Standard 40

Type 2

STB-650BR-H1-A-1

NSF Standard 40

Type 2

STB-650BR-H1-A-2

NSF Standard 40

Type 2

STB-650BR-H1-A-3

NSF Standard 40

Type 2

STB-650BR-H1-NA-1

NSF Standard 40

Type 2

STB-650BR-H1-NA-2

NSF Standard 40

Type 2

STB-650BR-H1-NA-3

NSF Standard 40

Type 2

STB-650BR-H2-A-1

NSF Standard 40

Type 2

STB-650BR-H2-A-2

NSF Standard 40

Type 2

STB-650BR-H2-A-3

NSF Standard 40

Type 2

STB-650BR-H2-NA-1

NSF Standard 40

Type 2

STB-650BR-H2-NA-2

NSF Standard 40

Type 2

STB-650BR-H2-NA-3

NSF Standard 40

Type 2

STB-650BR-H3-A-1

NSF Standard 40

Type 2

STB-650BR-H3-A-2

NSF Standard 40

Type 2

STB-650BR-H3-A-3

NSF Standard 40

Type 2

STB-650BR-H3-NA-1

NSF Standard 40

Type 2

STB-650BR-H3-NA-2

NSF Standard 40

Type 2

STB-650BR-H3-NA-3

NSF Standard 40

Type 2

STB-650P-1

NSF Standard 40

Type 2

STB-650PR-1

NSF Standard 40

Type 2

STB-730P-1

NSF Standard 40

Type 2

STB-730PR-1

NSF Standard 40

Type 2

Website

STB-500

NQ 3680 Class III

Type 2

STB-500B

NQ 3680 Class III

Type 2

STB-500BR

NQ 3680 Class III

Type 2

STB-500BRA

NQ 3680 Class III

Type 2

STB-570P

NQ 3680 Class III

Type 2

STB-570PR

NQ 3680 Class III

Type 2

STB-650P

NQ 3680 Class III

Type 2

STB-650PR

NQ 3680 Class III

Type 2

STB-650B

NQ 3680 Class III

Type 2

STB-650BR

NQ 3680 Class III

Type 2

STB-650BRA

NQ 3680 Class III

Type 2

STB-730P

NQ 3680 Class III

Type 2

STB-750PR

NQ 3680 Class III

Type 2

Presby Environmental, Inc

Enviro-Septic

Pinnacle Environmental

SPD 450

NSF Standard 40

Type 2

Website

SPD 600

NSF Standard 40

Type 2

SPD 750

NSF Standard 40

Type 2

SPD 900

NSF Standard 40

Type 2

SPD 1050

NSF Standard 40

Type 2

SPD 1200

NSF Standard 40

Type 2

SPD 1350

NSF Standard 40

Type 2

SPD 1500

NSF Standard 40

Type 2

CTD 450

NSF Standard 40

Type 2

CTD 600

NSF Standard 40

Type 2

CTD 750

NSF Standard 40

Type 2

CTD 900

NSF Standard 40

Type 2

CTD 1050

NSF Standard 40

Type 2

CTD 1200

NSF Standard 40

Type 2

CTD 1350

NSF Standard 40

Type 2

CTD 1500

NSF Standard 40

Type 2

Website

Enviro-Septic®

NQ 3680 Class II

Type 2

Enviro-Septic®

NQ 3680 Class III

Type 2

 

Search For NSF Certified Wastewater Treatment Units

Liability Insurance

BCOSSA Insurance program
 

Who is Acera Insurance? As of September 20, 2022, CapriCMW has officially merged with Alberta-based Rogers Insurance to become Acera Insurance, one of Canada’s largest independent, employee-controlled brokerages. Rogers Insurance and CapriCMW have had a collaborative relationship for nearly 20 years and together, with 1,100+ employees located across BC, Alberta, Ontario and the Yukon, Acera Insurance is positioned to bring even more value to our clients and local communities while remaining 100% Canadian-owned.

AceraInsurance_cmyk.png
CapriCMW_logo_Final_wTag_CMYK-01.jpg
Marlee Pateman ,  CAIB (HONS), RIBO
Client Executive, Commercial Insurance
Employee Owner
Telephone 250.869.3914    ext 3914  
Email This email address is being protected from spambots. You need JavaScript enabled to view it.

CapriCMW and Rogers Insurance have merged​ to become Acera Insurance. 

Learn more. 

Benefits to BCOSSA Members:

I would recommend the following additions/slight amendments in addition to what you currently have. This is based on common questions/concerns we have noticed:

-Limited Pollution coverage Included at no additional charge

-Volunteers and employees are automatically covered

-Simple Application with fast turn around times for quotes

-Errors and Omissions Coverage available upon request

-No Health Hazards Exclusion

     

 

Please call BCOSSA at 778 432-2120 for more information.

Welcome To The BCOSSA Website!

Spring will soon be here!

Our hours are 9 to 5 Monday to Friday. Holidays we are not open.

 Due to a new bank program we will now need the numbers on the back of your Credit card.

Appologies to the recent Membership renewals, we will be calling for that number to enable processing.

 

Reistered Practioners Survey Results

Have a look

ROWP Survey

 

 

 

 

 


 

22.jpg
37.jpg
83.jpg

BOSCCA © 2014. All Rights Reserved.